XGN15-12 modular sulfur hexafluoride ring network cabinet
Category:
XGN15-12 modular AC metal enclosed sulfur hexafluoride ring network switchgear (hereinafter referred to as ring network cabinet) is a new generation of high voltage electrical appliances successfully designed and developed by our company according to the requirements of domestic rural power and urban power network transformation by introducing advanced technology. Through strict type test and long-term operation assessment, all technical performance indexes have reached IEC298 and GB3906 standards.
key word:
Hotline:
Detailed introduction
Graphic details
XGN15-12 modular AC metal enclosed sulfur hexafluoride ring network switchgear (hereinafter referred to as ring network cabinet) is a new generation of high voltage electrical appliances successfully designed and developed by our company according to the requirements of domestic rural power and urban power network transformation by introducing advanced technology. Through strict type test and long-term operation assessment, all technical performance indexes have reached IEC298 and GB3906 standards. The main switch, operating mechanism and components of the ring main unit are SFL-12/24 type switchgear manufactured by ABB or FLN36-12D type SF6 switchgear manufactured in China. The original HAD/US type SF6 circuit breaker or VD4-S type vacuum circuit breaker manufactured by ABB can also be installed according to user needs. The operation modes are divided into manual and electric. The cabinet body is made of imported aluminum coated zinc plates processed by CNC machine tools and riveted. The protection level reaches | P3X, and it has reliable mechanical interlocking and anti misoperation functions. This product is characterized by small volume, light weight, beautiful appearance, simple operation, long service life, high parameters, no pollution, less maintenance, etc.

·The altitude shall not exceed 1000m; (If the altitude exceeds 1000m, the relevant provisions of DL/T593-1996 Technical Guidelines for Common Ordering of High Voltage Switchgear shall apply);
·Ambient air temperature: upper limit+40 ° C, lower limit - 50 ° C;
·Relative humidity: daily average value is not more than 95%, and monthly average value is not more than 90%;
·The surrounding air does not contain corrosive gas, combustible gas, water vapor and other obvious pollution;
·No frequent violent vibration.
|
name |
Company |
parameter |
|
Rated voltage |
kV | 12 |
|
Rated frequency |
Hz | 50/60 |
|
Rated current of main bus |
A | 630 |
|
Rated short-time withstand current of main circuit and grounding circuit |
kA/s | 20/3 |
|
Rated peak withstand current of main circuit and grounding circuit |
kA | 50 |
|
Rated short-circuit making current of main circuit and grounding return circuit |
kA | 50 |
|
Rated current breaking times of load switch |
次 | 100 |
|
Rated transfer current |
A | 1700 |
|
Maximum rated current of fuse |
A | 160 |
|
Open circuit of fuse switch |
kA | 31.5-50 |
|
Mechanical life |
次 | 2000 |
|
1min power frequency withstand voltage (effective value) interphase, ground/isolated fracture |
kV | 42/48 |
|
Lightning impulse withstand voltage (peak value) interphase, to ground/isolating fracture |
kV | 75/85 |
|
1min power frequency withstand voltage of secondary circuit |
kV | 2 |
|
Degree of protection |
IP3X | IP3X |
Users shall provide the following information when ordering products:
·Loop wiring scheme;
·Arrangement diagram and plane layout of switch cabinet;
·Schematic diagram of auxiliary circuit and control circuit in switch cabinet (if necessary);
·Other special requirements of the product shall be mentioned separately.
Related products
Online
Message
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in time, or please call us directly.